Farath Naseem Romana, Shaik Mobeen*, Soja Sara George, Shibu MP, Sravanthi Jagati, Juveria Fathima, Ayisha Nudrath, Mohammad Noorez Nasir
MNR Dental College and Hospital Sangareddy, Telangana, India
*Corresponding Author: Shaik Mobeen, Department of Oral medicine and Radiology, MNR Dental College and Hospital Sangareddy, India
Received: 04 March 2025; Accepted10 March 2025; Published: 28 March 2025
Class II malocclusions may be corrected by combinations of restriction or redirection of maxillary growth, distal movement of maxillary dentition, Experimental studies have shown that forces for Class II correction produced by extraoral traction and intermaxillary elastics cause posterior repositioning of the maxillary dental complex, as well as of the maxilla itself [1]. Besides exploiting the periodontal anchorage potential (teeth), additional anchorage aids are often needed to achieve maximal anchorage. The aids conventionally used for intraoral anchorage to enhance periodontal anchorage quality are trans palatal and lingual bars, Nance holding arch and intermaxillary elastics [2]. The anchorage in edgewise treatment is the most important factor that affects the treatment plan and result. Until now, various techniques to reinforce anchorage have been devised and used in orthodontic practice. Recently, several kinds of implant anchors providing absolute anchorage have attracted the attention of orthodontists. Among them, titanium screws, which were originally used for intermaxillary or bone ?xation, have the following advantages: minimal anatomic limitation for placement, lower medical cost, simpler placement surgery, and less discomfort after implantation when compared with dental implants for abutment. Therefore, titanium screws of various sizes have gradually come to be used for orthodontic absolute anchorage. However, there have been few human studies in which the success rates for various kinds of implant anchors were examined [3]. Anchorage is a critical component of en-masse retraction. Clinicians pay considerable attention to Newton’s third law- the law of action and reaction. They know that every action they take will have an equal and opposite reaction. Many approaches to treatment mechanics have been developed to ef?ciently retract anterior teeth [4]. In tooth-borne anchorage cases, complicated mechanics or supplementary appliances are needed to control anchorage. Extraoral appliances can provide stable anchorage but depend totally on patient cooperation. Lack of cooperation can result in anchorage loss and unsatisfactory treatment results; these have led to greater use of intraosseous anchorage [5]. It has become more practical to use implants for anchorage in orthodontic patients, Orthodontic screws expand the horizons of orthodontic treatment because they allow treatment to proceed successfully with virtually no anchorage loss and minimal patient cooperation. However, they are typically used as auxiliaries to the posterior anchor teeth during en-masse retraction with sliding mechanics. The mechanics of force application can be simple or complicated, according to the anchorage control. For anterior retraction, if the mini-implants are designed to accommodate arch wires, the number of teeth requiring bands or brackets can be reduced, moderating the risk of damage to the periodontium or enamel surfaces. Distalization of the maxillary dentition has been recognized as an important treatment approach for the correction of Class II malocclusions and it has been traditionally performed using headgear. However, known disadvantages of headgear appliances include poor aesthetics and dependence on patient compliance. In an attempt to overcome the limitations of headgear, several noncompliance devices such as distal jet and pendulum appliances were introduced. However, they often resulted in undesirable side effects such as extrusion and protrusion of the maxillary anterior teeth and extrusion, distal tipping, and distal rotation of the maxillary first molars [6].
The advent of temporary anchorage devices (TADs) has allowed better control over unwanted reciprocal movement of the anchor units, although miniscrew insertion in the interradicular region is associated with serious limitations, including a short range of action, coupled with the risk of root injury. Miniplates have been advocated as an alternative to avoid contact with adjacent roots in the area of insertion; however, their placement and removal require more invasive surgical procedures.6Orthodontics in its century of existence have had a lot of landmarks in its evolution, but very few can match the clinical impact made by micro-implants and the recently introduced infra-zygomatic crest (IZC) and buccal shelf (BS) orthodontic bone screws. Orthodontics in its century of existence have had a lot of landmarks in its evolution, but very few can match the clinical impact made by micro-implants and the recently introduced infra-zygomatic crest (IZC) and buccal shelf (BS) orthodontic bone screws. Many studies have been reported on the application and clinical ef?ciency of total arch distalization mechanics; however, studies about biomechanical effects such as stress and displacements on the teeth and the surrounding tissues are limited. finite element analysis (FEA), a common method in engineering, became a valuable option for evaluation of biomechanical factors in orthodontics [7,8].
The purpose of this study was to (1) Evaluate three-dimensional stress distribution and initial displacement of maxillary dentition under total arch distalization mechanics for correction of Angle’s Class II malocclusion using IZC bone screws and C-Palatal plate appliance in Pre-adjusted Edgewise Appliance (PEA) setup and finite element models and to (2) To compare biomechanical effects of the IZC bone screws and MCPP for total maxillary arch distalization.
Infrazygomatic Crest Bone Screws, Class II Malocclusion, Total Maxillary Arch
Infrazygomatic Crest Bone Screws articles, Class II Malocclusion articles, Total Maxillary Arch articles
To evaluate three-dimensional stress distribution and initial displacement of maxillary dentition under total arch distalization mechanics for correction of sagittal maxillary excess using posteriorly placed infra-zygomatic crest (IZC) bone screws with pre-adjusted edgewise fixed appliance and palatally placed modified C- palatal plate appliance (MCPP).
To evaluate the dental and skeletal effects of the IZC bone screws and MCPP for total maxillary arch distalization in treatment of Angle’s class II malocclusion by using finite element analysis.
To compare biomechanical effects of the IZC bone screws and MCPP for total maxillary arch distalization in treatment of Angle’s class II malocclusion by using finite element analysis.
In this study a maxillary arch was modelled on the basis of their CBCT images. For creating a finite element model, a computer aided design model was constructed from a dry young skull of an approximate age of 18 years. Age estimation was carried out by dental eruption pattern. Human maxillary skull bone without mandible was checked for defects or discontinuity in the craniofacial anatomy. FEM has been applied successfully to study stress and strain in the field of engineering and in living structure. A FEM was created from computed tomography (CT) images of dry skull of an adolescent (slice thickness, 0.5mm) Altair Hyperworks (Altair Engineering Inc., Troy, Michigan, USA) was used.
Adult patient with Angle’s class II malocclusion.
Maxillary model with all other permanent teeth present and with 3rd molar missing or extracted.
Apply Material Prosperities for Bone, PDL, teeth etc.
A force of 300 grams was applied on either side of the maxilla in model 1 with infrazygomatic crest bone screws (IZC).
In model 2 with modified C- palatal plate appliance (MCPP) 300 grams of force was applied on both the sides using elastomeric chains attached to palatal hooks of the MCPP.
In this study, the geometry of 3D finite element model of the maxilla and mandible with their periodontal structures, i.e., PDL, alveolar bone were constructed from a CBCT scan image of a skull [9]. These data were exported to 3D image processing and editing software-3D-Doctor (Able Software Corp., Lexington, Massachusetts, USA), stereolithographic (STL) model of each tooth was constructed).
A 0.019x0.025”-Stainless steel last archwire had been inserted in the bracket slot before starting the arch distalization.
With the help of GEOMAGIC modelling software, the geometric models were converted into finite element models. The finite element model represents geometry in terms of finite elements and the nodes. This process is called “discretization [10].” In this study, to model the irregular geometry of the teeth for maxilla, 4-noded tetrahedral shape was selected as the finite element.
The material properties of teeth, PDL, and alveolar bone used were the average values reported in literature. All materials employed for the finite element model study were taken to be isotropic, homogenous, and linearly elastic
All 3 Steps have been shown as a diagram below
From the raw CAD model proper base is formed for the jaw. This is used to apply constraints (fixed support) to the jaw.
This study has 2 models as follows:
Maxillary Model 1: Design consists of IZC bone screws (2mm ×12 mm) with PEA setup.
Maxillary Model 2: Design consists of MCPP with PEA setup.
Construction of MBT prescription brackets and archwire
This is the first step in FEM Study for any dental FEA Model Setup. Brackets are aligned and placed first so that there is no bend in the arch wire [12].
This was a stage for trial RUN of FEA. It was a stage for element quality check. Element qualities like Warpage, Aspect Ratio, Tet Collapse were checked & required modification were done in the model to improve the element quality.
Local re-meshing in some areas was considered to improve the overall mesh quality of the Finite Element Model14. All this was done to ensure generated mesh/element quality is within acceptable limit for FEA Solver. This process was performed for both Maxilla models.
Boundary Conditions define the way model is held or fixed in the FE space & the way forces are applied on the model.
Jaw Bone (Maxilla) need to be fixed at a point in FEA. Following images gives details on how the model was fixed in this study.
As per FEM, nodes on the selected surfaces were locked in all Degrees of Freedom. This restricted the displacement of these nodes in all direction. This way model was locked / fixed in the FEA space for solving [15].
Red path in image below for maxilla shows the location where nodes were locked in all degrees of freedom. This is the top face of the maxilla cast.
From above figure we can draw some conclusion. However, the images are brought on same scale for comparison. 2nd value on scale is set at 0.25 mm which is common for both the models. With this change we see both the models have same or similar displacement pattern.
As both images now have same pattern, we can say that the model with modified C - palatal plate appliance is having higher distillation compared to IZC bone screw. We see the same in result table for Displacement.
|
Maxillary Models |
Displacement in teeth in Distillation Direction (mm) |
|
Model – 1 IZC Screw |
0.288 |
|
Model – 2 C Palatal Plate |
0.318 |
Table 4: Displacement in teeth in Distillation Direction in model 1 and 2
We can see from above table that displacement in C Palatal Plate is about 9% higher than in IZC Screw. This means that the C Palatal Plate will have higher / faster distillation compared to IZC in clinical practice.
Following image shows Von. Mises Stress for Maxilla with both IZC & modified C - palatal plate Appliance.
Just as we did for displacement results, we are plotting the same Von. Mises Stress on same scale plot for better comparison and following are the result images.
From the Von. Mises Stress for maxilla in same scale we see following observations:
We can see the similar results for Compression & Tension Stress.
|
Maxillary Models |
Stress in Mpa |
||
|
Von. Mises in Jaw Bone |
Tension Stress |
Compression Stress |
|
|
Model – 1 IZC bone Screw |
0.217 |
0.159 |
0.126 |
|
Model – 2 Modified C Palatal Plate Appliance |
0.447 |
0.355 |
0.477 |
|
% Difference |
49% |
45% |
26% |
From the Von. Mises Stress for maxilla in same scale we see following observations:
We can see the similar results for Compression & Tension Stress.
|
Maxillary Models |
Stress in Mpa |
||
|
Von. Mises in Jaw Bone |
Tension Stress |
Compression Stress |
|
|
Model – 1 IZC bone Screw |
0.217 |
0.159 |
0.126 |
|
Model – 2 Modified C Palatal Plate Appliance |
0.447 |
0.355 |
0.477 |
|
% Difference |
49% |
45% |
26% |
Table 5: Tension and compression stress in model 1 and 2.
Miniscrews are commonly used for anchorage in distal movement of the maxillary dentition for treatment of Class II malocclusion, because of their advantages of minimal anatomic limitation, simple placement, and limited complications. Placement of miniscrews in the buccal interradicular region is one of the most common approaches used in distal tooth movement. Although the interradicular miniscrews may reduce complications related to soft tissue irritation, the limited interradicular space can obstruct tooth movement. Therefore, the infrazygomatic crest region is frequently selected for miniscrew insertion, because it not only has the thickest maxillary cortical bone but also is far from the dentoalveolar region [16]. The anatomic advantages of the infrazygomatic crest region contribute to better primary stability of miniscrews and provide the possibility for unobstructed tooth movement. However, because no well-accepted insertion protocol or sophisticated assistive device has been available for operators, anatomic research is needed for safe miniscrew insertion in this region. The FEM has been widely used in engineering; however, its application to the health sciences is relatively new, and because of multiple variables in real life, certain approximations and assumptions are needed [17]. The results of this study were obtained from a simulated model, from which biologic variabilities may occur. The resultant values should be interpreted only as a reference to aid clinical judgment. The limitations of the 3D FEM model include approximations in the material behaviours and shapes of the tissues."
Venkateswaran S, Rao V and Krishnaswamy NR. performed a study to describe the challenges of anchorage conservation in orthodontics, especially when multiple teeth are moved simultaneously. Headgear and intermaxillary elastics have traditionally been used in such situations, despite the unpredictability of headgear, the side effects of incisor extrusion and excessive rotation of the occlusal plane from Class II or Class III elastics, and the difficulty of obtaining patient compliance [18].
A finite element method was used for modelling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modelling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analysed and calculated with ANSYS software.
They concluded that according to the findings of their study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition.
Many studies have been conducted on the application and clinical efficiency of total maxillary arch distalization mechanics [19]; however, studies about biomechanical effects such as stress and displacements on the teeth and the surrounding tissues are limited. In-vivo studies are not quite sufficient in assessing biomechanical effects such as stress and displacement, finite element analysis, a common method in engineering, became a valuable option for evaluation of biomechanical factors in orthodontics.
The purpose of the study was to evaluate three-dimensional stress distribution and initial displacement of maxillary dentition under total arch distalization mechanics for correction of maxillary excess using posteriorly placed infra-zygomatic crest (IZC) bone screws - Model 1and modified C – palatal plate appliance (MCPP) – Model 2. Two geometric Maxillary models converted into finite element models; Model 1 and Model 2 with PEA setup.
Force levels for Model 1 with IZC bone screw includes total of 300 grams on either side of maxillary posterior segment and in Model 2 with modified C- palatal plate appliance (MCPP) 300 grams of force was applied on both the sides using elastomeric chains attached to palatal hooks of the MCPP.
Results showed that in the Model 1 with PEA setup the Von. Mises Stress in infrazygomatic crest bone screw (IZC) is almost 49% of that in Model 2 with modified C – palatal plate appliance (MCPP). Tension stress is also 45% in IZC of that in MCPP. Compression Stress in IZC model is 26% of that in MCPP.
Present study results showed that the displacement in modified C-palatal plate appliance (0.318 mm) is about 9% higher than in IZC screw (0.288). Von Mises stress in MCPP is 0.447 mm and the IZC is 0.217mm. Tension stress (mPa) in MCPP is 0.355 mm and 0.159 mm in IZC Screw. Compression stress in MCPP is 0.477mm and IZC screw is 0.126 mm.
To conclude Model 1 and Model 2 design provided an effective en masse distalization of the full maxillary arch. This study has shown that the displacement in MCPP is more than the IZC screw and the stress in MCPP is higher than the IZC screw. The study also shows that en masse distalization as a treatment option was predominantly chosen in late adolescence and young adults by using MCPP and IZC for treating class II div 1 malocclusion [20].
The study concluded that the modified C-palatal plate appliance (MCPP) anchorage showed significant en mass distalization of the maxillary arch. However, this was not significantly different from the Infrazygomatic crest (IZC) bone screws.
The displacement in modified C - palatal plate is about 9% higher than in IZC Screw. This means that the MCPP will have higher / faster distalization compared to IZC bone screws in clinical practice.
The posterior alveolus of the palate is a good alternative site for implant placement to bring about distal movement of the entire maxillary arch. The biomechanics involved appears to produce good treatment results with less risk of mini-implant failure and lesser need for repeated procedures.
Therefore, these results suggest that clinicians should consider using modified C – palatal plate appliance, especially in noncompliant Class II adolescent patients.