Differences in Poikilocapnic vs Isocapnic Hypoxia in Healthy Adults

Vol 9, Issue 4 Pages 250–256 Published: 13 Nov 2026

Verbruggen Jasmine1,2, De Vooght Wouter3, Hermans Ben2, De Vooght Pieter1, De Jongh Raf1,2*

1Department of Anesthesiology, Intensive Care and Emergency Medicine Ziekenhuis Oost Limburg Synaps Park 1 B 3600 Genk, Belgium

2Complementary Medical Center Europalaan 42 B 3600 Genk Belgium

3Department of Neurology Sint-Trudo Ziekenhuis: Diestersteenweg 100 B 3800 Sint-Truiden Belgium

*Corresponding author: De Jongh Raf, Department of Anesthesiology, Intensive Care and Emergency Medicine Ziekenhuis Oost Limburg Synaps Park 1 B 3600 Genk, Belgium. Email: Raf.dejongh@skynet.be

Received: 06 October 2026; Accepted: 16 October 2026; Published: 13 November 2026

Article Information
Citation: Verbruggen Jasmine, De Vooght Wouter, Hermans Ben, De Vooght Pieter, De Jongh Raf. Differences in Poikilocapnic vs Isocapnic Hypoxia in Healthy Adults. Journal of Biotechnology and Biomedicine. 9 (2026): 250-256.

DOI: 10.26502/jbb.2642-91280230

Share
Abstract

For calibration and determining the final accuracy of newly developed pulse oxygen saturation devices, oxygen saturation values measured by this device are paired with arterial blood samples during hypoxia. Arterial oxygen saturation is the golden reference to the tested pulse oximeter. The United States Food and Drug Administration and the International Organization for Standardization (ISO) 80601-2-61 (2026 and earlier) describe the guidelines for clinical studies with healthy volunteers for calibration and accuracy calculation of newly developed pulse oximeters based on photoplethysmography. Both poikilocapnic and isocapnic hypoxia are allowed and applied during open, non-randomised interventional studies to look for the accuracy of the test device. During ISO 80601-2-61-based studies using the isocapnic approach, measured end-tidal CO? values guide the concentration of CO? that is added to inspiratory hypoxic gas mixtures via a face mask. This allows the end-tidal CO? level to be kept constant by changing the inspiratory CO?. In contrast, during the poikilocapnic hypoxia approach, subjects breathe a hypoxic gas mixture without added CO?, via face mask or in a normobaric hypoxia room. Consequently, subjects hyperventilate for hypoxic compensation resulting in hypocapnia. Both hypoxia protocols present advantages and disadvantages regarding arterial oxygen saturation reflection by pulse oximeters placed on skin during ISO 80601-2-61-guided studies. This short review highlights assumed and proven differences between isocapnic or poikilocapnic human hypoxia experiments used for ISO 80601-2-61-guided hypoxia studies to determine final accuracy of a pulse oximeter test device.

Keywords

Poikilocapnic; Isocapnic Hypoxia; SpO₂; Oxygen; Hypocapnia

Poikilocapnic articles; Isocapnic Hypoxia articles; SpO₂ articles; Oxygen articles; Hypocapnia articles

Article Details

Introduction

For more than 50 years, pulse oxygen saturation (SpO₂) devices placed on the skin have been used to extend cardiopulmonary monitoring for patients. Later, thanks to decreased prices, miniaturisation, increased capacity to compute, or incorporation into consumer smartwatches, SpO₂ measurements are frequently used by the lay public.  Pulse oximeters need to be closely linked to arterial O₂ pressure (PaO₂). Some pulse oximeters sold to the public do not accurately reflect arterial oxygen saturation (SaO₂), mainly in the lower ranges of viable SpO₂ [1,2], whereas in practice (para)medical workers depend on these inaccurate SpO₂ values.

Most pulse oximeters placed on the skin use light emitting diodes (LEDs) with wavelengths in the red (+/- 660 nm) or near-infrared spectrum (+/- 940 nm) for skin illumination. Sometimes daylight, lamp light or flash light by a smartphone are used as light sources. Green LED (+/- 560 nm) light can be used, but green light has a very low penetration into the skin and undergoes significant absorption by skin tissue [3]. Reflected or transmitted light is captured by light diodes (or a camera), resulting in captured photoplethysmographic signals.  Reflected or absorbed light is highly, but not exclusively, dependent on the oxygenation status of hemoglobin in the red blood cells [4]. The amount of absorbed or reflected light is influenced by the tissue’s blood volume, which changes during the cardiac cycle, the so-called alternating current. In addition, acute differences in the microcirculation of the skin capillaries and arterioles can influence absorption or scattering of the LED light illuminating the skin. SpO₂ devices have at least two LEDs that are alternatingly active, sometimes with a pause between. The captured light is electronically separated referring to the respective illumination of a particular LED. As such, cardiac cycle dependent waveforms are reflected and SpO₂ is calculated by an in-device algorithm. This algorithm is manufacturer-dependent and, in most cases, kept secret. Settings of LEDs in terms of duration and magnitude of emitted light are strongly manufacturer-dependent and are determined during pre-clinical observations.

According to the ISO and FDA recommendations, human subjects undergo hypoxia with SaO₂ or SpO₂ down to 70 %. There is a required evaluation of SpO₂ test devices (TD) in pre-clinical studies. These are crucial and are performed by the manufacturer in in-house or external laboratories, frequently using breath holding leading to rather limited oxygen desaturations or using phantom devices. These preclinical calibration and accuracy evaluations are followed by studies in healthy volunteers undergoing hypoxia, first non-invasively comparing TD results with an approved reference SpO₂ device, whereafter TD is compared to SaO₂ measured in arterial blood samples by a reference CO-oximeter to calculate the definite accuracy of the TD’s SpO₂. Including healthy subjects, TD is tested during a feasibility and pivotal Investigational Device Exemption study for medical devices (here called: ISO-study).  ISO-studies are interventional, open and non-randomized designed experiments for accuracy calculation of these Class IIa devices. Melanin, present in varying amounts in the skin, heavily absorbs light and determines skin tone.  Effects of skin tone on the accuracy of TD is beyond the scope of this review.

In human life, hypoxia occurs in healthy subjects in altered environmental conditions (e.g. at high altitude, in a fire) or in diseased subjects under normal ambient conditions (e.g., respiratory diseases, heart failure, sleep apnea) or both. Hypoxia in experimental conditions might essentially differ in terms of progression of the induced inspiratory partial pressure of O₂ (PiO₂), positioning of the volunteer, exposed exercise, concomitant medication, gender, obesity, age, sleep, among other subject-independent factors such as changed death space. Hypoxia can be acute or chronic, continuous or intermittent, generalized or localized, hypo- or normobaric. Because both poikilocapnic (PH) and isocapnic hypoxia (IH) are allowed to be used for the ISO-studies, based on our experience with PH, we looked into the literature to discriminate both techniques in terms of cardiovascular and pulmonary physiology, bias-inducing conditions, influencing factors on SpO₂ measurements, accuracy, among others.

Throughout this overview, abbreviations used for (partial) pressures include gas pressure (P) followed by the name of the considered gas: inspiratory P (Pi), partial pressure of end-tidal CO₂ (PetCO₂), ambient or atmospheric P surrounding the volunteer (Pamb), and alveolar P (Palv). Air contains approximately 20,9 % of oxygen, whatever the altitude.  Therefore, partial pressure of a gas compared to atmospheric P in gases is denoted in % avoiding more scientific terms as kPa or mmHg (Torr). PH stands for poikilocapnic hypoxia, and pH is used for the proton concentration in the blood that reflects its acidity or alkalinity.

Description of isocapnic hypoxia and poikilocapnic hypoxia techniques

Most hypoxia facilities for ISO-studies are clinical laboratories staffed by trained employees. ISO-studies recruit healthy volunteers, normally between 18 and 50 years old. Diseased volunteers, heavy smokers, subjects who are anemic or have abnormal hemoglobin or red blood cells, and subjects with low basal SpO₂ are excluded from these ISO-studies. All volunteers breathe spontaneously without mechanical support. Five stable PambO₂ plateaus are defined based on the reference SpO₂ device worn by the volunteer during both IH and PH: normal SpO₂ >97%, SpO₂ between 97-92; between 92-85, between 84-77 and between 77-70 %. Interindividual SpO₂ is known to vary during a particular oxygen concentration level, but also intra-individual SpO₂ variability is noted (see further). This implies that the PiO₂ is not pre-set in the ISO-study, but is adapted to the volunteer’s SpO₂ measured by the reference SpO₂.

During IH, subjects wear a well-fitting face mask, connected to tubes, mostly with unidirectional valves. Gas mixtures contain nitrogen and oxygen. PetCO₂ is followed by mainstream or sidestream CO₂ monitors. PiCO₂ is increased to maintain or slightly exceed the pre-hypoxia PetCO₂ level, a technique called PetCO₂ clamping. Around 2% PiCO₂ is administered but the level is adapted during the ISO-studies using IH to maintain PetCO₂. Gas flows in the used system may significantly influence gas pressures, thus control of Pi in the mask seems necessary, but is ignored to report. Advantages of IH include shorter periods of hypoxemia for the subject, lower investment costs compared to a hypoxia room, coworkers not undergoing hypoxia, but theoretically more skilled coworkers (N ≥ 1) near the subject are warranted. In general, due to the activity in the laboratory room surrounding the volunteers, subjects experience more external stimuli compared to PH. PetCO₂ needs to be measured which is not the case during PH in hypoxia rooms. During IH, the duration of plateaus of a particular hypoxia level takes about 15 minutes, immediately followed by a new level of hypoxia. Death space ventilation is slightly higher in humans using a face mask, compared to non-masked ventilation by volunteers in a hypoxia room. Increased death space can result  in increased PaCO₂-PetC02 gradients.

During PH, volunteers can receive a face mask with inspired gas mixtures only containing tracing amounts of CO₂, ranging between 0 and 0,04%. However, most PH studies use a hypoxia room with steadily decreasing oxygen levels to approximately 9,5 %. When using face masks, subjects undergoing PH feel discomfort due to sudden oxygen decrease with accompanying pronounced hypocapnia. In hypoxia rooms, several subjects can be measured simultaneously, in our center limited to 3 for a non-invasive ISO-study, and 2 for the invasive ISO-study. The room is inflated with 3% of oxygen created by a Vacuum Pressure Swing Absorption system. Continuous output of sensors for O₂, CO₂, Patm and humidity near the ceiling of the hypoxia room are recorded. The sensor for PambO₂ guides the generation of hypoxia in the room. As hypoxia rooms are almost hermetically closed, O₂ levels do not vary during the plateaus without 3 % O₂ injections. Variation of PambO₂ is thus avoided during these ISO-studies with PH.

Subjects breathe spontaneously in the room, with a slightly increased PambCO₂ level due to expired CO₂ by volunteers and coworkers in the room without immediate wash-out of CO₂ out of the room. A skilled nurse or an anesthesiologist has to accompany the volunteers during hypoxia. These coworkers can receive oxygen up to 1 L/min by a nasal tube, when needed, to keep their SpO₂ above 85%.  Oxygen of 1L/min inflated into the room does not change the speed of decrease of PambO₂ of the room, the latter decreases exponentially from 21 % to 9,5 in about 82 minutes during the non-invasive part of the study. As inflated air contains 3 % of oxygen, the decrease of PambO₂ down to 9,5 % is grosso modo linear. PH seems a more physiological approach, as normal PaCO₂ with low PaO₂ is rare in non-ventilated subjects. It creates a more tranquil environment for volunteers because of less external stimulation. During PH in hypoxia rooms, volunteers can adapt progressively to decreasing PiO₂. Disadvantages of PH include fatigue and sometimes dizziness observed in some volunteers at lower SpO₂ with hypocapnia, longer duration of hypoxia, and exposure of one coworker to limited hypoxia. Observers can detect sleep in volunteers, however this was always denied by the subjects.

Variability of SpO₂ during hypoxia

Intra-individual variability of SpO₂, also called entropy, and inter-individual variability of SpO₂ to a particular PambO₂ correlates to the depth of hypoxia [5,6]. Entropy was also detected during our PH ISO-study in volunteers submitted to hypoxia in sitting or supine position [7]. In these PH studies, also a variability in SaO₂ was noted during the plateaus with stable ambient oxygen concentrations (non-published data). Interestingly, during several studies SpO₂ progressively decreased during a stable Pamb plateau (non-published data, [8]).

During ISO-studies using PH or IH, volunteers are breathing spontaneously and small changes in breathing pattern can be caused by, for instance, an external stimulus including coughing or periods of periodic breathing. Consequently, these small changes in respiration, referred to as respiratory variability, influence PalvO₂, and cardiopulmonary physiology with a concomitant rapid change in the lung's blood oxygen saturation. Oxygen saturation during lowered PambO₂ is located on the steep part of the oxygen-hemoglobin dissociation curve [9], so small changes in nominal PaO₂ may result in higher changes of SpO₂. Whatever the physiological explanation, SpO₂ variability has huge practical impacts during ISO-studies, making rigorous timing of capturing of SpO₂ and SaO₂ values used for pairing in statistical analysis.  Due to entropy, SaO₂ needs to be registered at the time of sampling of non-diluted blood into an anticoagulating syringe.  The average SpO₂ reflection during a time period specified by the manufacturer will be used for pairing.  Timing needs to be clearly defined in the clinical investigation protocol before starting the ISO-study. It is, however, noted that reference devices, including the CO-oximeter, have an accuracy of about 2%.

Respiratory responses of subjects undergoing IH or PH.

Ventilatory responses to hypoxia are determined by multiple factors such as alveolar gas concentrations, alveolar-capillary gas exchange, systemic capillary-tissue gas exchange, lung tissue circulation delay, and feedback responses. Indeed, hypoxia determines the signals of peripheral chemoreceptors to the respiratory center [10]. Hypocapnia influences mainly the central chemoreceptor output [11]. High interindividual variability of ventilatory responses during hypoxia is described, including gender-dependent differences [12].

Both IH and PH elicit a biphasic ventilatory response called the hypoxic ventilatory response (HVR), characterized by an initial rapid increase in ventilatory minute volume followed by a progressive decline over the following minutes called the hypoxic ventilatory decline (HVD), which is affirmed by mathematical modelling [13]. It has been shown that breathing frequency and tidal volume are under different neural control. The growth phase of HVR is linked to the decline in arterial PO₂ and stimulation of the peripheral chemoreflexes, but under poikilocapnic conditions arterial PCO₂ plays a role.  Indeed, the growth phase is higher during IH compared to PH [14]. Mechanisms underlying the decay phase are more obscure, perhaps related to decreased peripheral chemoreflex sensitivity to O₂. Arguments can be found that CO₂ is also involved [12,14,15]. During face mask use, in contrast to hypoxic room use, theoretically a small increase in positive end-expiratory airway pressures can influence oxygen transport, but these changes are too small to take in consideration if gas fluxes in the ventilatory system are well controlled.

In a cross-over clinical study comparing ventilatory changes during IH or face mask PH, healthy volunteers were exposed for 20 minutes to hypoxia with end tidal oxygen of 10% [14]. Human ventilatory response to PH resulted in a hypocapnia (approximately - 5 mmHg), with a slight non-significant increase of minute ventilation without change in the breathing frequency, but a temporal increase in tidal volume. As expected, during IH higher tidal volumes, and increased breathing frequency were noted. During IH a decreased duration of the inspiration and expiration without significant difference compared with PH was noted in other studies [16]. Results of studies show different and contradictory information. Indeed, a higher variability of the respiratory rate was dependent on SpO₂, while tidal volume is not during PH [8], although others did not confirm all of these results [17,18].

Effects of IH and PH on PaCO₂ and pH.

The PaCO₂-PalvCO₂ gradient seems not to differ if comparing normoxia compared to hypoxia [19]. This is not confirmed by others, as in healthy subjects under normal environmental circumstances PaCO₂‑PetCO₂ gradients exist, and are measured to be about 2 to 3 mmHg in healthy subjects. But the gradient was dependent on PambO₂ [20]. The amount of binding of CO₂ to hemoglobin is described by a non-S shaped CO₂ dissociation curve and is thus PaCO₂ dependent. Respiratory alkalosis during progressive PH is too short to be compensated by metabolic acidosis, resulting in an increased blood and cerebral pH. This increased pH during lowered PaCO₂ is not without consequences for an individual undergoing hypoxia. In our hypoxia room, PH with progressive decreasing PambO₂ down to 9.5%, PaCO₂ never decreased lower than 30 mmHg in eligible blood samples of volunteers who gave informed consent for using their results in addition to the captured SpO₂ and SaO₂ values (N > 100 volunteers, N > 2000 blood gases) but PaCO₂ varied substantially during plateaus of ambient oxygen (non-published results). The highest pH was found to be 7,533 in these arterial blood samples. Adverse events during PH with PambO2 < 12 %, fatigue, dizziness or small cognitive declines were observed, but disappeared immediately after normalisation of PambO₂.

Haldane effect on the oxy-hemoglobin dissociation curve

Hemoglobin is the most important oxygen carrier in the blood of humans.  Oxygen binds to hemoglobin in the red blood cells at varying degrees of affinity, depending on the biochemical environment. The relation between PaO₂ and oxygen saturation of hemoglobin is reflected by a S-wave oxygen dissociation curve. Binding of O₂ to hemoglobin is subject-dependent, and is referred to as the Haldane-effect, as this binding is influenced by temperature, pH and CO₂ among other factors. In the lungs, during physiological circumstances, PCO₂ decreases as CO2 is diffused to the alveoli. This decrease in CO₂ implies that oxygen is better bound to hemoglobin. On the other hand, in the peripheral circulation PCO₂ is increased and binding of oxygen to hemoglobin is weaker, resulting in a better transfer of O₂ out of the red blood cells. During PH, however, PaCO₂ and alveolar CO₂ are decreased, which results in more tightly binding of O₂ to hemoglobin compared to IH protocols.

In the periphery, the lower the PCO₂ the lower the transport of O₂ to cells as O₂ is better bound to hemoglobin during hypocapnia.  Compared to the hypocarbia during PH, during normocarbia in IH protocols O₂ binds at a lower degree to hemoglobin but in the periphery O₂ is more rapidly transferred to tissues. In conjunction with the effects of hypoxia and hypocapnia on microcirculation in the skin, one can hypothesize that the SpO₂-SaO₂ gradient is different between both techniques used for ISO-studies. The use of PH or IH might result in different calibration or accuracy results of the TD. As medical pulse oximeters are produced and distributed for all medical indications, it is possible that SpO₂ reflection differs between IH and PH tested devices during different medical situations.

Periodic breathing and PH

During PH, hypoxic responses result in hypocapnia. Hypocapnia affects mainly central chemoreceptors to decrease the ventilation in order to maintain the subject’s pH. Peripheral chemoreceptors detecting hypoxia act faster compared to the slow reacting central chemoreceptors detecting hypocapnia [21]. The depressed ventilation can induce apnea in some subjects, most frequently encountered in males during sleep [22]. This phenomenon of temporal decrease or absence of ventilation is referred to as periodic breathing. Periodic breathing is frequently accompanied by increased SpO₂ variability. In our ISO-studies with 18 awake and freely breathing volunteers undergoing PH, periodic breathing was observed only in male subjects [23], and periodic breathing was dependent on the body mass index and age of the volunteer. It is noted that also healthy females can develop periodic breathing during experimental PH [24]. To the best of our knowledge, periodic breathing is not induced by IH.

Cardiopulmonary effects of hypoxia

By complex neuronal pathways built-up during evolution of mammals, PaCO₂ or pH and PaO₂ trigger the central or peripheral respiratory centers. In addition, ventilatory responses to acute hypoxia or hypocapnia may alter the activity of both the sympathetic or parasympathetic autonomic nervous systems. The integrated cardiac and respiratory system display complicated dynamics that are affected by intrinsic feedback mechanisms controlling their interaction.

Clinically, acute effects of exposure to hypoxia lead to an increased cardiac output, mainly induced by an increase in heart rate with a modest increase of the mean arterial pressure. Heart rate variability, a value reflecting the autonomic nervous system, is changed during hypoxia [25]. Hypoxic exposure is shown to directly change blood flows, which is tissue-dependent (see microcirculatory changes). At the pulmonary level hypoxia elicits vasoconstriction. On the other hand, systemic blood pressure is kept relatively constant by the activity of arterial baroreceptors during hypoxia studies.

During alveolar hypoxia a hypoxic pulmonary vasoconstriction (HPV) becomes prominent which is reciprocally PalvO₂-dependent [26]. Acetazolamide is a carbonic anhydrase inhibitor that induces acidosis, mild diuresis and can inhibit hypoxic pulmonary vasoconstriction. This indicates that CO₂ can interfere with pulmonary vasoconstriction during hypoxia [27]. During normal environmental circumstances and in healthy subjects, vasculature of the lungs responds to local hypoxia in order to change ventilation/perfusion mismatch to optimize PaO₂. This results in altered lung blood flows to avoid lung regions with changed ventilation/perfusion quotients to be perfused. During systemic hypoxia, pulmonary arterial pressure increases significantly due to vasoconstriction [28]. The early phase of vasoconstriction starts within 100 msec, peaking at 5‑20 min as a result of transient elevations of intracellular calcium concentrations. The decay is peaking at 60‑120 min as a result of myofibrillar calcium‑sensitization coupled with enhanced endothelial release of vasoconstrictive compounds and nitric oxide changes [28]. In vivo, animal or human studies show that hypercapnia induced vasoconstriction of the pulmonary vessels, but hypocapnia blunted this response to hypoxia. Clinically, in free breathing healthy humans undergoing hypoxia with different PetCO₂ levels, it was shown that hypercapnia accentuated hypoxic pulmonary vessel resistance directly with increased tricuspid regurgitation, whereas other regulatory mechanisms seem of less importance [29]. The contribution of dysregulation of the pulmonary vasculature to result in differences in SpO₂-SaO₂ gradients during IH compared to PH and the consequences on the accuracy of pulse oximeters is not studied in detail.

Effects on peripheral circulation

Several mechanisms exist to regulate blood flow in the skin [30]. Hypoxia influences the microcirculation [31] although the cutaneous blood flow seems to react differently to hypoxia compared to other tissues [32].  Mechanisms involved during changes of the microcirculation are not completely understood during healthy or disease circumstances [33]. Vascular autoregulation can be elicited by local hypoxia but is probably not influenced by changes in sympathetic or parasympathetic output. Local vascular regulatory mechanisms can thus influence the local blood flow in, and the density of, open small vessels < 100 micrometers and venules.

Skin blood flow is important during photoplethysmography and fast acting vascular mechanisms are seen. During one heart beat microvascular responses are noted. The regulatory mechanisms can influence photoplethysmographic SpO₂ signals as they are dependent on the amount of oxy-hemoglobin or deoxy-hemoglobin under the TD. This can probably influence a SaO₂-SpO₂ gradient depending on the type of measurements.

To the best of our knowledge, neither central temperature nor peripheral temperature at the area of Sp02 monitors are followed during ISO-studies. Setting of ambient temperature is important during these studies. It is clear that skin and core temperatures are of utmost importance in validation of SpO₂ test devices.

Effects on cerebral blood flow and cognitive function

The cerebral circulation uses CO₂ and O₂ as strong signals to adjust blood flow, primarily to maintain adequate oxygen delivery and match blood supply to the brain's metabolic needs. PH presents the brain with a difficult interaction between two opposing blood gas stimuli, hypercapnia causes vasodilation and increases cerebral blood flow (CBF), while hypocapnia decreases CBF by vasoconstriction.

During 48 hours of hypoxia, CBF followed the decline in PCO₂ during PH, whereas during IH CBF remained unchanged [34]. Steinback et al [13] reported an increase in CBF during IH whereas this response was biphasic during PH. Initially an increase in cerebral vascular resistance with decreased cerebral blood flow was observed. After a while, cerebral vascular resistance normalized and cerebral blood flow rose again. The near equivalency of middle cerebral artery blood flow velocity during IH and PH for about 20 min indicates that the hypoxic stimulus dominates late in the PH exposure during these human studies.

On the other hand, during IH and PH, it was demonstrated that cerebral autoregulation impairment in isocapnic hypoxia can be prevented with hypocapnia, highlighting the integrated nature of hypoxic cerebrovascular control, which is under strong CO₂ influence [35].

Hypoxia is associated with a decrease in cognitive function [36]. Bloomfield et al. demonstrated a neuroprotective effect of CO₂ in complex psychomotor task performance. Psychomotor performance decrease is seen during PH, and not during IH [37].

Interpretation

After acute exposure to hypoxia, most physiological responses show a growth phase followed by a decay phase. Pulse oximeters claim to reflect SaO₂. SaO₂-SpO₂ gradients of 2 to 3% are allowed in newly developed SpO₂ devices during ISO-studies, before application in patients. The type of hypoxia given during ISO protocols, IH or PH, may present differences in terms of the subject’s ventilation, cardiovascular responses, PalvO₂, oxygen uptake and delivery in lungs and microcirculation in the skin.

Further comparative research is necessary to decide whether IH or PH tested pulse oximeters differ in reflecting SaO₂ during pathological conditions, an ultimate desire of clinicians. These conditions may include low perfusion cardiovascular diseases, altitude sejourns, sepsis, and ventilated or anesthetized patients. Probably the ideal pulse oximeter will never exist, as reference devices also have deviations in reflecting the true SaO₂ values. Considering rapid intra-individual variabilities of SpO₂, including variabilities of ventilation, cardiovasculatory and microcirculatory tones, timing of blood withdrawal to pair SaO₂ with SpO₂ averages reflected by a TD is absolutely necessary to define the accuracy of a pulse oximeter TD. Hopefully, the rapid increase of computing capacity can help us to unravel SaO₂-SpO₂ differences for optimal clinical reflection of SaO₂ by SpO2.

References

  1. Lipnick MS, Feiner JR, Au P, et al. The Accuracy of 6 Inexpensive Pulse Oximeters Not Cleared by the Food and Drug Administration: The Possible Global Public Health Implications. Anesth Analg 123 (2016): 338-345.
  2. Trivedi NS, Ghouri AF, Lai E, et al. Pulse oximeter performance during desaturation and resaturation: a comparison of seven models. J Clin Anesth 9 (1997): 184-188.
  3. Gokhale S. Emerging Technology for Noninvasively Measuring Oxygen Saturations. Chest 169 (2026): 401-410.
  4. Nitzan M, Nitzan I, Arieli Y. The Various Oximetric Techniques Used for the Evaluation of Blood Oxygenation. Sensors (Basel) 20 (2020): 4844.
  5. Jiang Y, Costello JT, Williams TB, et al. A network physiology approach to oxygen saturation variability during normobaric hypoxia. Exp Physiol 106 (2021): 151-159.
  6. Costello JT, Bhogal AS, Williams TB, et al. Effects of Normobaric Hypoxia on Oxygen Saturation Variability. High Alt Med Biol 21 (2020): 76-83.
  7. de Haan M, Gerrits J, Verbruggen STJ, et al. Oxygen Saturation Variability in Sitting and Supine Position during Normobaric Hypoxia; a Controlled Desaturation Study. Books of Abstracts, 10th European Hypoxia Symposium (2023): 6-7.
  8. Kohlbrenner AA, Marillier M, Randy H, et al. Characterisation of the acute hypoxic response using breathing variability parameters: A pilot study in humans. Respir Physiol Neurobiol 315 (2023): 104096.
  9. Luks AM, Swenson ER. Pulse oximetry at high altitude. High Alt Med Biol 12 (2011): 109-119.
  10. Pfoh JR, Steinback CD, Vanden Berg ER, et al. Assessing chemoreflexes and oxygenation in the context of acute hypoxia: Implications for field studies. Respir Physiol Neurobiol 246 (2017): 67-75.
  11. Guyenet PG, Bayliss DA. Neural Control of Breathing and CO₂ Homeostasis. Neuron 87 (2015): 946-961.
  12. Rispen L, Marks D, Green S. Dynamic ventilatory responses of females and males to acute isocapnic and poikilocapnic hypoxia. Respir Physiol Neurobiol 245 (2017): 57-64.
  13. Ursino M, Magosso E, Avanzolini G. An integrated model of the human ventilatory control system: the response to hypoxia. Clin Physiol 21 (2001): 465-477.
  14. Steinback CD, Poulin MJ. Cardiovascular and cerebrovascular responses to acute isocapnic and poikilocapnic hypoxia in humans. J Appl Physiol 104 (2008): 482-489.
  15. Duffin J. Measuring the ventilatory response to hypoxia. J Physiol 584 (2007): 285-293.
  16. Jubran A, Tobin MJ. Effect of isocapnic hypoxia on variational activity of breathing. Am J Respir Crit Care Med 162 (2000): 1202-1209.
  17. Bloomfield PM, Fisher JP, Shaw DM, et al. Cocoa flavanols protect cognitive function, cerebral oxygenation, and mental fatigue during severe hypoxia. J Appl Physiol 135 (2023): 475-484.
  18. Bloomfield PM, Green H, Fisher JP, et al. Carbon dioxide protects simulated driving performance during severe hypoxia. Eur J Appl Physiol 123 (2023): 1583-1593.
  19. Tymko MM, Hoiland RL, Kuca T, et al. Measuring the human ventilatory and cerebral blood flow response to CO₂: a technical consideration for the end-tidal-to-arterial gas gradient. J Appl Physiol 120 (2016): 282-296.
  20. Yamauchi H, Ito S, Sasano H, et al. Dependence of the gradient between arterial and end-tidal P(CO₂) on the fraction of inspired oxygen. Br J Anaesth 107 (2011): 631-635.
  21. Tymko MM, Young D, Vergel D, et al. The effect of hypoxemia on muscle sympathetic nerve activity and cardiovascular function: a systematic review and meta-analysis. Am J Physiol Regul Integr Comp Physiol 325 (2023): R474-R489.
  22. Pramsohler S, Schilz R, Patzak A, et al. Periodic breathing in healthy young adults in normobaric hypoxia equivalent to 3500 m, 4500 m, and 5500 m altitude. Sleep Breath 23 (2019): 703-709.
  23. van Scheppingen D, de Haan M, Gerrits M, et al. Development of periodic breathing in awake healthy individuals under controlled progressive hypoxia. Respir Physiol Neurobiol 340 (2026): 104512.
  24. Lombardi C, Meriggi P, Agostoni P, et al. High-altitude hypoxia and periodic breathing during sleep: gender-related differences. J Sleep Res 22 (2013): 322-330.
  25. Botek M, Krejčí J, De Smet S, et al. Heart rate variability and arterial oxygen saturation response during extreme normobaric hypoxia. Auton Neurosci 190 (2015): 40-45.
  26. Oeung B, Pham K, Olfert IM, et al. The normal distribution of the hypoxic ventilatory response and methodological impacts: a meta-analysis and computational investigation. J Physiol 601 (2023): 4423-4440.
  27. Swenson ER. Carbonic anhydrase inhibitors and hypoxic pulmonary vasoconstriction. Respir Physiol Neurobiol 151 (2006): 209-216.
  28. Licker M, Hagerman A, Jeleff A, et al. The hypoxic pulmonary vasoconstriction: From physiology to clinical application in thoracic surgery. Saudi J Anaesth 15 (2021): 250-263.
  29. Croft QP, Formenti F, Talbot NP, et al. Variations in alveolar partial pressure for carbon dioxide and oxygen have additive not synergistic acute effects on human pulmonary vasoconstriction. PLoS One 8 (2013): e67886.
  30. Cracowski JL, Roustit M. Human Skin Microcirculation. Compr Physiol 10 (2020): 1105-1154.
  31. Jung C, Jung F, Kelm M. The microcirculation in hypoxia: The center of the battlefield for oxygen. Clin Hemorheol Microcirc 63 (2016): 169-172.
  32. Tymko MM, Young D, Vergel D, et al. The effect of hypoxemia on muscle sympathetic nerve activity and cardiovascular function: a systematic review and meta-analysis. Am J Physiol Regul Integr Comp Physiol 325 (2023): R474-R489.
  33. De Backer D, Donadello K, Taccone FS, et al. Microcirculatory alterations: potential mechanisms and implications for therapy. Ann Intensive Care 1 (2011): 27.
  34. Poulin MJ, Fatemian M, Tansley JG, et al. Changes in Cerebral Blood Flow During and After 48 H of Both Isocapnic and Poikilocapnic Hypoxia in Humans. Exp Physiol 87 (2002): 633-642.
  35. Querido JS, Ainslie PN, Foster GE, et al. Dynamic cerebral autoregulation during and following acute hypoxia: role of carbon dioxide. J Appl Physiol 114 (2013): 1183-1190.
  36. McMorris T, Hale BJ, Barwood M, et al. Effect of acute hypoxia on cognition: A systematic review and meta-regression analysis. Neurosci Biobehav Rev 74 (2017): 225-232.
  37. Bloomfield PM, Green H, Fisher JP, et al. Carbon dioxide protects simulated driving performance during severe hypoxia. Eur J Appl Physiol 123 (2023): 1583-1593.
Article Views
106
Total Views
Download PDF
Article Details
  • Volume9
  • Issue4
  • Pages250–256
  • Published13 Nov 2026
  • ISSN2642-9128
  • DOI10.26502/jbb.2642-91280230
Journal

Journal of Biotechnology and Biomedicine

Impact Factor: 5.3
Submit Manuscript
© 2016–2026, Copyrights Fortune Journals. All Rights Reserved.